Western blot transfer completed in 10 minutes!
The Thermo Scientific Pierce Fast Western Transfer System reduces protein transfer time from SDS-PAGE to a membrane from 45 minutes to only 10 minutes. The system consists of two parts, the Pierce Fast Semi-Dry Transfer Buffer and the Pierce Fast Semi-Dry Blotter. Use our cost-effective Western Blot Transfer System to obtain membranes that are Western blotting-ready in 10 minutes without the need to purchase special consumables.
About the Pierce Fast Transfer System
The Pierce Fast Semi-Dry Blotter is an Western transfer apparatus that enables rapid transfer of proteins or nucleic acids from a gel to a membrane. When used with the Thermo Scientific Pierce Fast Semi-Dry Transfer Buffer, efficient protein transfer can be achieved in under 10 minutes. The Pierce Fast Semi-Dry Blotter also can be used for conventional semi-dry transfer using traditional buffers and western blotting protocols. The major advantages of fast semi-dry blotting are reduced buffer consumption, uniform electric field, high transfer efficiency, shorter transfer times and higher throughput (up to 4 mini-gels).
The Pierce Fast Semi-Dry Transfer Buffer is designed to accelerate the transfer of proteins from SDS-PAGE gels to nitrocellulose or PVDF membranes in 7-10 minutes compared with the traditional 45-minute transfer. This semi-dry transfer buffer is part of the Pierce Fast Western System and is also compatible with other semi-dry transfer units. The formulation does not require methanol and is supplied as a 10X concentrate that is simply diluted with deionized water before use.
Highlights of the Pierce Fast Semi-Dry Transfer System:
- Pierce Fast Semi-Dry Blotter
- Fast – transfer protein from gel to membrane in 7-10 minutes
- Sensitive – same transfer efficiency as other semi-dry or wet-transfer units
- Economical – no special consumables needed
- Robust – transfer up to 4 gels at one time
- Versatile – use homemade or pre-cast gels
- Pierce Fast Semi-Dry Transfer Buffer
- Optimized – formulated for accelerated transfer
- Non-hazardous – no methanol required, eliminating hazardous disposal
- Compatible – use with all major SDS-PAGE gels (Tris-HEPES, Tris-Glycine, Bis-Tris and Tris-HCl)
- Flexible – use with any semi-dry transfer unit; use with nitrocellulose or PVDF membranes
- Easy to use – simply dilute the 10X concentrated formula in ultrapure water
|
|
| Transfer efficiency of the Thermo Scientific Pierce Fast Transfer System is comparable to existing methods. A549 whole cell lysates were prepared for SDS-PAGE and loaded onto a NuPAGE* 4-12% Bis-Tris Gel (1.0 mm x 10 well) using the following protein amounts: 16 µg, 8 µg, 4 µg and 2 µg. After electrophoresis, gels were transferred to nitrocellulose membrane using either Pierce Fast Semi- Dry Transfer System or the Invitrogen iBlot* Dry Blotting System. Resulting membranes were probed for PRKDC, EGFR, PLK1, CDC2 and Cyclophilin B using the Pierce Fast Western Blotting Kit. |
| Thermo Scientific Pierce Fast Transfer System is a rapid and economical alternative other popular transfer systems. |
| |
Pierce Fast Transfer System |
iBlot Transfer System |
Tank Transfer System |
| Time |
7-10 minutes
|
7 minutes
|
|
Cost per transfer
(for 1 mini gel) |
$4
|
$13
|
$11
|
| Special Consumables |
No
|
Yes, transfer stacks
|
|
| Environmentally friendly |
Yes, no methanol required, no plastic or metal waste or additional consumables
|
No, requires disposal of packaging, sponge and copper from iBlot transfer stacks
|
No, requires addition of methanol
|
| Throughput |
Up to 4 gels per run
|
Up to 2 gels per run
|
|
| Recommended high-current power supplies for the Pierce Fast Semi-Dry Transfer Blotting Apparatus. |
| Model |
Maximum Current |
| Owl EC-200XL |
2.0 Amps |
| Consort EV202 (Germany, France) |
2.0 Amps |
| Note: Any power supply capable of generating at least 25 Volts is compatible with the Pierce Semi-Dry Transfer Apparatus. If lower voltage power supplies are used then the transfer area must be decreased or the transfer time must be increased for complete protein transfer. |
Related Products:
Pierce Fast Western Blotting Kits – Fast transfer deserves fast development
Membranes and Filter Paper
CL-Xposure Film for Western blotting
Pierce Western Blot Signal Enhancer – It's like intensifying screens in a bottle
Restore PLUS Western Blot Stripping Buffer
Browse all Pierce Western Blotting Kits
|