Advanced
Part of Thermo Fisher Scientific
Thermo Scientific - Pierce Protein Research Products  

Document Center

  Certificate of Analysis
  Product Instructions
  MSDS
  Print This Page
  Request A Catalog

User Profile

Email Address:
Password:
 
  I Forgot My Password
  Register
  Why Register?

Shopping Cart

  Ordering Information
Shipping & Handling
Security Info
Returns Info
  Current Order
Cart is Empty
Quick Order



Email Sign-up Email Sign-up

Subscribe to our RSS feed!  RSS



 


YOU ARE HERE:  Browse Product Catalog > Western Blotting, ELISA and Cell Imaging > ELISA Reagents and Coated Microplates > Coated Microplates > Copper Coated Plates, High Capacity  


Pierce Copper Coated Plates, High Binding Capacity 

Boost plate-based assay performance by binding more His-tagged protein.

Thermo Scientific Pierce Copper Coated Plates are ideal for analyzing polyhistidine-tagged fusion proteins by ELISA-based methods. Proteins that contain a succession of several histidine residues at the amino or carboxyl terminus have a strong binding affinity for metals such as copper. These copper-coated plates are available as clear, white or black plates that can be used with colorimetric, chemiluminescent or fluorescent detection methods, respectively.

Pierce Copper Coated Plates have High Binding Capacity (HBC) because they are coating using an exclusive process that increases the amount of histidine-tagged protein that will bind to the plate surface. Although copper is less discriminating in its binding specificity than Nickel, the higher binding capacity of these plates is ideal for high throughput screening applications that need improved sensitivity and greater dynamic range.

Highlights:

  • Quantitate previously undetectable histidine-tagged proteins
  • Wider dynamic range with four-fold greater capacity than regular nickel chelate-coated plate
  • Copper chelate provides greater binding capacity than nickel
  • The detection limit is 0.1 pg of polyhistidine tagged fusion protein per well
  • Pre-blocked for the ultimate convenience

Binding performance of nickel vs. copper coated plates. Comparison of Thermo Scientific Pierce Nickel Coated Plates to Pierce Copper Coated High Binding Capacity (HBC) Plates. Performance was evaluated comparing the amount of fluorescent signal produced by captured His-tagged fluorescent protein.
Binding comparison of Nickel and Copper Coated  Microplates.

Note: Copper coated plates are for use with purified His-tagged proteins. Typical cell lysates contain non-his-tagged proteins that may bind to copper, which can reduce binding capacity and signal-to-noise ratios. For cell lysates, use Thermo Scientific Pierce Nickel Coated Plates.


Ordering Information
Certificate of AnalysisCertificate of Analysis   Product InstructionsProduct Instructions   MSDSMSDS
Buy Product # Description Pkg. Size Files Price
Add 15143 Copper Coated, High Binding Capacity Plates (clear, 96-well) 5 plates Product Instructions MSDS for product # 15143 Copper Coated, High Binding Capacity Plates (clear, 96-well) $205.00
Add 15146 Copper Coated, High Binding Capacity Plates (clear, 8-well strips) 5 plates Product Instructions MSDS for product # 15146 Copper Coated, High Binding Capacity Plates (clear, 8-well strips) $221.00
Add 15147 Copper Coated, High Binding Capacity Plates (white, 96-well) 5 plates Product Instructions MSDS for product # 15147 Copper Coated, High Binding Capacity Plates (white, 96-well) $221.00
Add 15148 Copper Coated, High Binding Capacity Plates (black, 96-well) 5 plates Product Instructions MSDS for product # 15148 Copper Coated, High Binding Capacity Plates (black, 96-well) $221.00

Learn more about other Thermo Scientific Life Science Research Products
Biopolymers Cell Culture High Content Screening  
Nucleic Acid Technologies PCR Reagents & Plastics RNAi Technologies  European Sales

 © 2010 Thermo Fisher Scientific Inc.

PO Box 117, Rockford, IL 61105 USA
1-800-874-3723  or  815-968-0747

Trademarks Privacy Statement