Peptide Retention Time Calibration Mixture


Heavy peptide mixture for column assessment and peptide retention time prediction.

Peptide Retention Time Calibration Mixture

The Thermo Scientific Pierce Peptide Retention Time Calibration Mixture enables reversed phase liquid chromatography (LC) and mass spectrometry (LC-MS) users to optimize and confirm correct operation of their equipment.

The Pierce Peptide Retention Time Calibration Mixture is used to optimize and assess LC parameters, identify the total peptide elution window, and optimize MS parameters. Testing the mixture frequently throughout the lifetime of a column or including it in quantitative samples makes it possible to monitor and normalize LC-MS performance between samples and over time. When used with Thermo Scientific Pinpoint 1.1 software, the calibration mixture can predict peptide retention times based upon peptide sequence or relative retention time between instruments. The mixture can also be used with Pinpoint software to establish normalized collision energies between platforms. This allows normalization of methods and eases the transfer of quantitative methods between LC-MS platforms. Pinpoint software, sample files, tutorials, and videos can be downloaded from the Thermo Proteomics Portal.

Highlights:

  • Assess chromatography and MS instrument performance
  • Predict peptide retention across multiple instrument platforms
  • Predict peptide retention time from sequence using calculated hydrophobicity factor
  • Optimize scheduled MS acquisition windows for improved quantification and increased multiplexing
  • Normalize collision energies between instruments and platforms
  • Normalize results for variation in retention times and peak intensities between runs

Product Details:

The Pierce Peptide Retention Time Calibration Mixture contains 15 synthetic heavy peptides mixed at an equimolar ratio that elute across the chromatographic gradient. The observed retention times and hydrophobicity factors (HF) for these calibrant peptides are fit to a linear equation to determine the slope of the retention time/HF relationship. This equation and the HF of an uncharacterized peptide are then used to predict retention time.

Thermo Scientific Pierce Peptide Retention Time Calibration Mixture Components and Properties. The peptide sequences, peptide masses and chromatographic behavior of each component of the Peptide Retention Time Calibration Mixture are given above. The position and identity of the heavy lysine+ 8Da or arginine+10Da isotope-labeled amino acid in each sequence is indicated in bold.
# Peptide Sequence Mass Hydrophobicity
Factor (HF)
1 SSAAPPPPPR 985.5220 7.56
2 GISNEGQNASIK 1224.6189 15.50
3 HVLTSIGEK 990.5589 15.52
4 DIPVPKPK 900.5524 17.65
5 IGDYAGIK 843.4582 19.15
6 TASEFDSAIAQDK 1389.6503 25.88
7 SAAGAFGPELSR 1171.5861 25.24
8 ELGQSGVDTYLQTK 1545.7766 28.37
9 GLILVGGYGTR 1114.6374 32.18
10 GILFVGSGVSGGEEGAR 1600.8084 34.50
11 SFANQPLEVVYSK 1488.7704 34.96
12 LTILEELR 995.5890 37.30
13 NGFILDGFPR 1144.5905 40.42
14 ELASGLSFPVGFK 1358.7326 41.18
15 LSSEAPALFQFDLK 1572.8279 46.66

The prediction of peptide retention time assists in the development of multiplexed, high throughput mass spectrometric assays. The Pierce Peptide Retention Time Calibration Mixture and Thermo Scientific Pinpoint software streamline the transition from qualitative protein discovery results to the development of targeted MS assays on Thermo Scientific triple quadrupole, Orbitrap, Exactive, and ion trap mass spectrometers. The Pierce Peptide Retention Time Calibration Mixture permits optimization and regular assessment of chromatographic performance and for rapid development of multiplexed, scheduled targeted MS assays for the quantification of dozens to hundreds of peptide targets per run.

Peptide Retention Time for Calibration of Reversed Phase LC MS columns.
Chromatographic Analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture. A.The Peptide Retention Time Calibration Solution (250fmol) was analyzed in duplicate on a Thermo Scientific LTQ XL Orbitrap Mass Spectrometer using a self-packed column (75µm x 20cm) containing Magic™ C18 (Michrom Bioresources) using a 0.25% per minute gradient of Buffer A (0.1% formic acid) and Buffer B (0.1% formic acid/99.9 % acetonitrile) at 300nL per minute. B. The Retention Time Calibration Solution was also analyzed on a Thermo Scientific TSQ Vantage Mass Spectrometer using a Thermo Scientific Hypersil Gold C18 column (1.0 x 150mm, Part No. 25005-150165) with a 1.0% per minute gradient at 120µL per minute. Numbered peaks correspond to the calibrant peptides described above.

 

More Product Data

Related Resources:

FASTA-formatted sequences of Peptide Retention Time Calibration Mixture peptides (download zip file)
SRM transition of Peptide Retention Time Calibration Mixture peptides (download csv file)
Thermo Proteomics Software Portal
Mass Spectrometry Sample Prep Workflow - Product Guide
Peptide design technical guide
Peptide synthesis technical guide
Mass spectrometry technical guide
Quantitative proteomics technical guide

Related Products:

Other MS Calibration Solutions
Trypsin and other Protein Sample Prep Tools
C18 Spin Tips and other Peptide Sample Prep Tools
Heavy Protein In Vitro Protein Expression Kits
Custom Peptides, HeavyPeptides and Peptide Libraries
FT-MS, Ion trap, Quadrupole, and Orbitrap LC-MS systems


Ordering Information
 
Product # Description Pkg. Size Instructions MSDS CofA Price
88320 Peptide Retention Time Calibration Mixture
Formulation: Mixture of 15 synthetic heavy peptides at 0.5µM each.
Sufficient For: 5 to 100 uses
50µL Product Instructions for product #88320 Peptide Retention Time Calibration Mixture MSDS for product #88320 Peptide Retention Time Calibration Mixture Certificate of Analysis for product #88320 Peptide Retention Time Calibration Mixture $67.00

Add to cart
88321 Peptide Retention Time Calibration Mixture
Formulation: Mixture of 15 synthetic heavy peptides at 5µM each.
Sufficient For: 200 to 4000 uses
200µL Product Instructions for product #88321 Peptide Retention Time Calibration Mixture MSDS for product #88321 Peptide Retention Time Calibration Mixture Certificate of Analysis for product #88321 Peptide Retention Time Calibration Mixture $438.00

Add to cart

Instructions | MSDS | CofA
Product Instructions | MSDS | CofA  

Share This Page
 
 

Follow Us
  Email Sign-up  Email Announcements

 



Antibodies  |   Molecular Biology   |   Cell Biology   |  Thermo Scientific  |   * Trademarks  |   Privacy Statement
© 2014 Thermo Fisher Scientific Inc.   |   3747 N Meridian Rd, Rockford, IL USA 61101   |   1-800-874-3723  or  815-968-0747