Fast Western Blot Kits, ECL Substrate


Obtain your Western blot results in about an hour without buying an instrument.

Pierce Fast Western Kit, ECL Substrate. Western blots developed in about an hour.

The Thermo Scientific Pierce Fast Western Blot Kit, ECL Substrate contains optimized reagents that shorten the time required to perform a typical chemiluminescent Western blot from 4 hours down to approximately 55 minutes.

The kit provides all the reagents necessary to complete a Western blot being probed with a mouse or rabbit primary antibody. The protocol requires minimal hands-on time and yields results comparable to classic Western blotting with ECL. The included Pierce ECL Substrate produces a chemiluminescent signal, which is detected using photographic or other imaging methods. Blots can be repeatedly exposed to film to obtain optimal results or stripped of the primary antibody and immunodetection reagents and reprobed.

Highlights:

  • Fast – all the sensitivity of Pierce ECL substrate and saving 4 to 5 hours per blot
  • Convenient – no expensive hardware or vacuum required; no clogging issues
  • Simple – optimized protocol makes Western blot analysis easier than ever
  • Economical – cost as little as $8 per blot; no expensive consumables or extra equipment
  • Excellent stability – kit is stable for 1 year stored at 4°C
  • Easy – complete kit gives you all the components you need to block and probe and develop a blot with your mouse or rabbit primary antibody

Product Details:

The Pierce Fast Western Blot Kit is reagent-based system that provides optimized reagents for blocking, antibody dilution and detection of Western blots with Pierce ECL substrate. The protocol is a quick, efficient and economic way to obtain Western blot results without the hassle of buying an instrument and the consumables required by other popular rapid Western blotting systems. No vacuum pump is needed so there are never any clogged lines or membranes that can occur when using instrument-based systems. Because there is no apparatus, there is no need to buy disposable blotting trays that limit the number of blots processed at one time.

Pierce Fast Western Blot Kit results are identical to classical Western blot protocol.
 

Panels A and B contained 10, 2, 0.4 and 0.08µg of protein from A549 cell lysates in lanes 1-4, respectively.

Panels C and D contained 2, 1, 0.5, 0.25 and 0.125µg of 293T cell lysate in lanes 1-5 of Panel C and 25, 12.5, 6.25, 3.1 and 0.39µg in lanes 1-5 of Panel D.

Protein detection:
Panel A.
Mouse anti-Cyclin D1 antibody (BD Pharmingen) on PVDF.
Panel B. Rabbit anti-Beta Catenin antibody (LabVision) on PVDF.
Panel C. Mouse anti-GAPDH antibody (Millipore) on nitrocellulose.
Panel D. Rabbit anti-Cdk2 antibody (Upstate) on PVDF.
Comparable results obtained with classic Western blotting protocol and Thermo Scientific Pierce Fast Western Blot Kit, ECL Substrate. The detection sensitivity for various target proteins was compared using the Fast Western Blot Kit and the classical Western blot protocol.

 

Mutliplex Western blot for hsp90 and CTSK using Pierce Fast Western Kit, ECL Multiplex Experiment with Thermo Scientific Pierce Fast Western Blot Kit, ECL Substrate.
C57BL/6 mice bone marrow cells were stimulated with M-CSF (50ng/ml) and RANKL (50ng/ml) to induce differentiation into osteoclasts. Total cell lysates on PVDF were probed with 0.2µg/m rabbit anti-hsp90 and mouse anti-cathepsin K (Santa Cruz Biotechnology). Data generated by Lai-Chu Wu, Department of Molecular and Cellular Biochemistry, Ohio State University, Columbus, Ohio.

Mutliplex Western blot for SAM68 using Pierce Fast Western Kit, ECL Fast detection of His-tagged SAM68 protein purified using a Ni column from E. coli lysate. Lane 1. Lysate only, Lane 2. Column flow-through, Lanes 3-4. Wash and Lanes 5-8. Elution fractions. Fractions on PVDF were probed with rabbit anti-His-tag primary antibody (Santa Cruz Biotechnology). Data generated by Brenda Suh-Lailam and Joan Hevel, Department of Chemistry and Biochemistry, Utah State University, Logan, Utah.
 
Researcher generated data using the Fast Western Blot Kit, ECL Substrate.

 

Comparision of common Western blotting protocols. Side by side comparison of the steps and times required to complete a Western blot (post transfer and before development with substrate) using a classical protocol, the reagent-based Thermo Scientific Pierce Fast Western System, and the instrument-based SNAP i.d.™ System (Millipore Corp).
Protocol Steps Classical protocol Pierce Fast System SNAP i.d.™ System
Block/Pretreat 60 min - - - -
Primary antibody 60 min 30 min 10 min
Wash 45 min - - 1 min
Secondary antibody 60 min 10 min 10 min
Wash 45 min 15 min 1 min
Total Time 270 min 55 min 22 min
Key limitations Preparation of fresh non-fat dry milk blocking buffer each time For use with mouse or rabbit primary antibodies Only 2 full-sized blots per cycle. Strips limited by the format of the blot holders available. Reliable vacuum source required

 

The Thermo Scientific Pierce Fast Western Blot Kit is a cost-effective means to obtain Western blot results quickly. This table provides a brief cost of reagents and required consumables used in a classical Western protocol, the Pierce Fast Western reagent-based system and Millipore SNAP i.d.™ system.
Western blot reagents Classical
Protocol
Pierce Fast
System
SNAP i.d.
System
Blot holder for instrument - - - - $7.33
Blotting membrane (NC) $2.48 $2.48 $2.48
Blocking buffer $0.02 - - $1.32
Wash buffer (TBST) $1.48 - - $1.48
Secondary antibody conjugate $0.15 - - $0.15
Detection substrate (ECL) $1.43 - - $1.43
Film (5x7) $1.01 $1.01 $1.01
Kit's price per blot - - $7.92 - -
Total price per blot $6.57 $11.41 $15.20
Prices based on 2008 Thermo Scientific Pierce Western Blot Reagents.

Related Products:

Pierce G2 Fast Blotter
Membranes and Filter Paper
CL-Xposure Film for Western blotting
Pierce Western Blot Signal Enhancer
Restore PLUS Western Blot Stripping Buffer
Browse all Pierce Western Blotting Kits


Ordering Information
 
Product # Description Pkg. Size Instructions MSDS CofA Price
35050 Pierce Fast Western Blot Kit, ECL Substrate
Formulation: Multi-component kit
Sufficient For: 25 mini blots probed with mouse or rabbit primary antibodies

Kit Contents:
Fast Western Antibody Diluent, 500mL
Fast Western 10X Wash Buffer, 250mL
Fast Western Optimized HRP Reagent, 25mL
Pierce ECL Detection Reagent 1, 125mL
Pierce ECL Detection Reagent 2, 125mL
1L kit Product Instructions for product #35050 Pierce Fast Western Blot Kit, ECL Substrate MSDS for product #35050 Pierce Fast Western Blot Kit, ECL Substrate Certificate of Analysis for product #35050 Pierce Fast Western Blot Kit, ECL Substrate $221.00

Add to cart
35055 Pierce Fast Western Blot Kit, ECL Substrate
Formulation: Multi-component kit
Sufficient For: 5 mini blots probed with mouse or rabbit primary antibodies

Kit Contents:
Fast Western Antibody Diluent, 100mL
Fast Western 10X Wash Buffer, 50mL
Fast Western Optimized HRP Reagent, 5mL
Pierce ECL Detection Reagent 1, 25mL
Pierce ECL Detection Reagent 2, 25mL
200mL kit Product Instructions for product #35055 Pierce Fast Western Blot Kit, ECL Substrate MSDS for product #35055 Pierce Fast Western Blot Kit, ECL Substrate Certificate of Analysis for product #35055 Pierce Fast Western Blot Kit, ECL Substrate $109.00

Add to cart

Instructions | MSDS | CofA
Product Instructions | MSDS | CofA  

Recommend this page

Follow Us
Email Sign-up  Email Announcements

You may also need
23209 - Bovine Serum Albumin Standard Ampules, 2mg/mL

23227 - BCA Protein Assay Kit

66810 - Slide-A-Lyzer Dialysis Cassettes, 10K MWCO, 12mL

66380 - Slide-A-Lyzer Dialysis Cassettes, 10K MWCO, 3mL

23235 - Micro BCA Protein Assay Kit

 



Antibodies  |   Molecular Biology   |   Cell Biology   |  Thermo Scientific  |   * Trademarks  |   Privacy Statement
© 2014 Thermo Fisher Scientific Inc.   |   3747 N Meridian Rd, Rockford, IL USA 61101   |   1-800-874-3723  or  815-968-0747