Update profile
    Change password
    Sign out

Overview of Immunohistochemistry

Immunohistochemistry (IHC) combines anatomical, immunological and biochemical techniques to identify discrete tissue components by the interaction of target antigens with specific antibodies tagged with a visible label. IHC makes it possible to visualize the distribution and localization of specific cellular components within cells and in the proper tissue context. While there are multiple approaches and permutations in IHC methodology, all of the steps involved are separated into two groups: sample preparation and labeling.

Page Contents:

Protein Methods Library Home

 

 

 

Learn more...

IHC Troubleshooting Guide

View products...

IHC Reagents and Kits

IHC immunohistochemistry fluorescent tissue antibody antibodies streptavidin biotin biotinylated cytokeratin
Fluorescent IHC detection of cytokeratin 18 in colon carcinoma tissue. Human colon carcinoma sections were incubated with a biotinylated anti-cytokeratin 18 antibody and then fluorescently-labeled using Thermo Scientific Pierce Streptavidin-Conjugated DyLight 633. Thermo Scientific Pierce Hoechst stain was also used to fluorescently label cell nuclei.
View products...

Streptavidin DyLight Fluor Conjugates

Hoechst Stain

Introduction

History

The principle of IHC has been known since the 1930s, but it was not until 1942 that the first IHC study was reported. Coons et al. (1942) used FITC-labeled antibodies to identify Pneumococcal antigens in infected tissue. Since then, improvements have been made in protein conjugation, tissue fixation methods, detection labels and microscopy, making immunohistochemistry a routine and essential tool in diagnostic and research laboratories.

 

Applications

IHC is used for disease diagnosis, drug development and biological research. Using specific tumor markers, physicians use IHC to diagnose a cancer as benign or malignant, determine the stage and grade of a tumor, and identify the cell type and origin of a metastasis to find the site of the primary tumor. IHC is also used in drug development to test drug efficacy by detecting either the activity or the up- or down-regulation of disease targets.

Samples are prepared on individual slides, or multiple samples can be arranged on a single slide for comparative analysis, such as with tissue microarrays. IHC slides can be processed and stained manually, while technological advances now provide automation for high-throughput sample preparation and staining. Samples can be viewed by either light or fluorescence microscopy, and advances in the last 15 years have improved the ability to capture images, quantitate multiparametric IHC data and increase the collection of that data through high content screening.

Learn more...

Immunohistochemistry (IHC) vs. Immunocytochemistry (ICC)

Sample Preparation

While using the right antibodies to target the correct antigens and amplify the signal is important for visualization, complete preparation of the sample is critical to maintain cell morphology, tissue architecture and the antigenicity of target epitopes.  

Tissue Collection and Perfusion

Patient or animal biopsies, or whole animal organs, are collected for preservation and IHC analysis, depending on the requirements of the assay. Tissue must be rapidly preserved to prevent the breakdown of cellular protein and tissue architecture. Often, the tissue is perfused, or rinsed of blood, prior to preservation to prevent the detection of hematologic antigens that may interfere with the detection of target antigens. Tissue perfusion is performed on anesthetized animals by using a peristaltic pump to exsanguinate the animal and rinse the vasculature with sterile saline to remove all blood components from the entire animal. The target organ or tissue can then be collected for IHC.

 

Tissue Fixation

Fixation chemically crosslinks proteins or reduces protein solubility, which can mask target antigens during prolonged or improper fixation. Therefore, the right fixation method must be optimized based on the application and the target antigen to be stained.

The most common fixative is formaldehyde, a semi-reversible, covalent crosslinking reagent that can be used for perfusion or immersion fixation for any length of time, depending on the level of fixation required. Other fixatives are available, and their use depends on the antigens that are being sought.

Learn more...

Fixation Strategies and Formulations
GAPDH IHC poly-HRP streptavidin tissue antibody antibodies enzyme immunohistochemistry
GAPDH IHC poly-HRP streptavidin tissue antibody immunohistochemistry antibodies enzyme negative control
Detection of biotinylated GAPDH in colon carcinoma by chromogenic IHC. Fixed and paraffin-embedded human colon carcinoma sections were incubated with biotinylated cytokeratin18 antibody (top panel) or blocking buffer alone as a negative control (bottom panel). The samples were then incubated with Thermo Scientific Pierce Streptavidin Poly-HRP Conjugate, and the signal was developed with Thermo Scientific Pierce Metal Enhanced DAB.
View products...

Formaldehyde

Streptavidin Poly-HRP Conjugate

Metal Enhanced DAB Kit

Tissue Embedding

Fixed tissue samples are embedded in paraffin to maintain the natural shape and architecture of the sample during long-term storage and sectioning for IHC.

Samples too sensitive for either chemical fixation or the solvents used to remove the paraffin are encased in cryogenic embedding medium and then snap-frozen in liquid nitrogen.



Sectioning and Mounting

The decision to section tissue is dependent upon the application used; for example, whole mount IHC, with sample thickness up to 5 mm, does not require sectioning, while small samples for which multiple staining procedures are needed may require sectioning.

Formalin-fixed, paraffin-embedded tissues are sectioned into slices as thin as 4 to 5μm with a microtome. These sections are then mounted onto glass slides that are coated with an adhesive. This adhesive is commonly added by surface-treating glass slides with 3-aminopropyltriethoxysilane (APTS) or poly-L-lysine, which both leave amino groups on the surface of the glass to which the tissue directly couples. Alternatively, slides may be coated with physical adhesives, including gelatin, egg albumin or Elmer's glue. After mounting, the sections are dried in an oven or microwave in preparation for deparaffinization.

Frozen sections are cut using a pre-cooled cryostat and mounted to adhesive glass slides. These sections are often dried overnight at room temperature and fixed by immersion in pre-cooled (-20°C) acetone, although the drying step is sometimes skipped depending on the target antigens and tissue used.

View products...

3-aminopropyltriethoxysilane (APTS)

Epitope (Antigen) Recovery

The paraffin from formalin-fixed, paraffin-embedded sections must be completely removed for the antibodies to reach the target antigens. Xylene, a flammable, toxic and volatile organic solvent is commonly used to remove the paraffin from IHC slides, although commercial alternatives are available.

Formaldehyde fixation generates methylene bridges that crosslink proteins in tissue samples; these bridges can mask antigen presentation and prevent antibody binding. Formalin-fixed, paraffin-embedded sections commonly require a treatment to unmask the antibody epitopes, either by heat (heat-induced epitope retrieval; HIER) or enzymatic degradation (proteolytic-induced epitope retrieval; PIER).


Learn more...

Paraffin Removal and Antigen Retrieval

Quenching/Blocking Endogenous Target Activity

For staining approaches that depend on biotin, peroxidases or phosphatases for the amplification or enzymatic detection of target antigens, quenching or masking endogenous forms of these proteins prevents false positive and high background detection. The general strategies include physically blocking or chemically inhibiting all endogenous biotin or enzyme activity, respectively.

Learn more...

Methods to Block Endogenous Targets

Blocking Nonspecific Sites

Although antibodies show preferential avidity for specific epitopes, antibodies may partially or weakly bind to sites on nonspecific proteins (also called reactive sites) that are similar to the cognate binding sites on the target antigen. In the context of antibody-mediated antigen detection, nonspecific binding causes high background staining that can mask the detection of the target antigen. To reduce background staining in IHC, ICC and any other immunostaining application, the samples are incubated with a buffer that blocks the reactive sites to which the primary or secondary antibodies may otherwise bind. Common blocking buffers include normal serum, non-fat dry milk, BSA or gelatin, and commercial blocking buffers with proprietary formulations are available for greater efficiency.

Learn more...

Blocking Strategies for IHC
IHC vs. ICC

Sample Labeling

Immunodetection

Detecting the target antigen with antibodies is a multi-step process that requires optimization at every level to maximize the signal detection.

Both primary and secondary antibodies are diluted into a buffer to help stabilize the antibody, promote the uniform dissemination throughout the sample and discourage nonspecific binding. While one diluent may work with one antibody, the same diluent may not work with another antibody, demonstrating the need for optimization for each antibody.

Rinsing the sample in between antibody applications is critical to remove unbound antibodies and also to remove antibodies that are weakly bound to nonspecific sites. Rinse buffers are usually simple solutions of only a few components, but the right components must be considered to maximize sample washing and minimize interference with the signal detection.

Antibody-mediated antigen detection approaches are separated into direct and indirect methods. These methods both use antibodies to detect the target antigen, but the selection of the best method to use depends on the level of target antigen expression and availability and also the readout desired. Most indirect methods employ the inherent binding affinity of avidin to biotin to localize a reporter to the target antigen and amplify the signal that is detected.

IHC target antigens are detected through either chromogenic or fluorescent means, and the type of readout depends on the experimental design. For fluorescent detection, the reporter that the primary or secondary antibody is conjugated to is a fluorophore that is detected by fluorescent microscopy. Chromogenic detection is based on the activites of enzymes, most often horseradish peroxidase (HRP) or alkaline phosphatase (AP), which form colored, insoluble precipitates upon the addition of substrate, such as DAB and NBT/BCIP, respectively.

Learn more...

Immunodetection Reagents, Methods, Techniques and Optimization Strategies for IHC

Learn more...

IHC Troubleshooting Guide

β-Galactosidase Staining

Instead of using antibodies to detect the target antigen, β-galactosidase can be identified in tissue samples by employing the inherent enzymatic activity of the protein. β-galactosidase catalyzes 5-bromo-4-chloro-3-indoyl-β-D-galactopyranoside (BCIG or X-Gal) to form 5,5'-dibromo-4,4'-dichloro-indigo, an insoluble blue enzymatic product. For IHC, frozen sections are incubated with X-Gal along with an inducer, IPTG, to generate the chromogenic response.

View products...

X-Gal and IPTG

Counterstaining

Counterstains give contrast to the primary stain and can be cell structure-specific. These single-step stains are usually added after antibody staining.

Learn more...

IHC Counterstains

Sealing the Stained Sample

After all staining is completed, the sample should be preserved for long-term usage and storage and to prevent enzymatic product solubilization or fluorophore photobleaching. Sealing the sample by mounting a coverslip with an appropriate mountant stabilizes the tissue sample and stain. An antifade reagent should also be included if fluorescent detection will be performed to prolong fluorescence excitation. The coverslip can then be sealed with clear nail polish or a commercial sealant after the mountant has cured to prevent sample damage.

Learn more...

IHC Troubleshooting Guide

Sample Visualization

Once the sections are prepared, the samples are viewed by light or fluorescent microscopy. Depending on the antibody detection method, one can perform confocal microscopy for greater detail and enhanced imaging capabilities. Additionally, samples can be analyzed by high content screening for rapid quantitation and comparison of data from multiple samples.

 

References

  1. Coons, A.A., et al. (1942) J. Immunol. 45, 159-170.
 
Written and/or reviewed by Jared Snider, Ph.D.

Instructions | MSDS | CofA
Product Instructions | MSDS | CofA  

Recommend this page

Follow Us
Email Sign-up  Email Announcements

 



Antibodies  |   Molecular Biology   |   Cell Biology   |  Thermo Scientific  |   * Trademarks  |   Privacy Statement
© 2014 Thermo Fisher Scientific Inc.   |   3747 N Meridian Rd, Rockford, IL USA 61101   |   1-800-874-3723  or  815-968-0747