Overview of ELISA

Enzyme-linked immunosorbent assays (ELISAs) are plate-based assays designed for detecting and quantifying substances such as peptides, proteins, antibodies and hormones. Other names, such as enzyme immunoassay (EIA), are also used to describe the same technology. In an ELISA, an antigen must be immobilized to a solid surface and then complexed with an antibody that is linked to an enzyme. Detection is accomplished by assessing the conjugated enzyme activity via incubation with a substrate to produce a measureable product. The most crucial element of the detection strategy is a highly specific antibody-antigen interaction.

Protein Methods Library Home

 

 

Introduction

ELISAs are typically performed in 96-well (or 384-well) polystyrene plates, which will passively bind antibodies and proteins. It is this binding and immobilization of reagents that makes ELISAs so easy to design and perform. Having the reactants of the ELISA immobilized to the microplate surface makes it easy to separate bound from nonbound material during the assay. This ability to wash away nonspecifically bound materials makes the ELISA a powerful tool for measuring specific analytes within a crude preparation.

A detection enzyme or other tag can be linked directly to the primary antibody or introduced through a secondary antibody that recognizes the primary antibody. It also can be linked to a protein such as streptavidin if the primary antibody is biotin labeled. The most commonly used enzyme labels horseradish peroxidase (HRP) and alkaline phosphatase (AP). Other enzymes have been used as well, but they have not gained widespread acceptance because of limited substrate options. These include β-galactosidase, acetylcholinesterase and catalase. A large selection of substrates is available for performing the ELISA with an HRP or AP conjugate. The choice of substrate depends upon the required assay sensitivity and the instrumentation available for signal-detection (spectrophotometer, fluorometer or luminometer).

Pierce Assay Development Technical Handbook

Order Free Literature.
Assay Development Handbook

ELISA Formats

ELISAs can be performed with a number of modifications to the basic procedure. The key step, immobilization of the antigen of interest, can be accomplished by direct adsorption to the assay plate or indirectly via a capture antibody that has been attached to the plate. The antigen is then detected either directly (labeled primary antibody) or indirectly (labeled secondary antibody). The most powerful ELISA assay format is the sandwich assay. This type of capture assay is called a “sandwich” assay because the analyte to be measured is bound between two primary antibodies – the capture antibody and the detection antibody. The sandwich format is used because it is sensitive and robust.

An ELISA can also be performed as a competitive assay. This is common when the antigen is small and has only one epitope, or antibody binding site. One variation of this method consists of labeling purified antigen instead of the antibody. Unlabeled antigen from samples and the labeled antigen compete for binding to the capture antibody. A decrease in signal from purified antigen indicates the presence of the antigen in samples when compared to assay wells with labeled antigen alone.

Fluorescent tags and other alternatives to enzyme-based detection can be used for plate-based assays. Despite not involving reporter-enzymes, these methods are also generally referred to as a type of ELISA. Likewise, wherever detectable probes and specific protein binding interactions can be used in a plate-based method, these assays are often called ELISAs despite not involving antibodies.

Browse Products...

ELISA Reagents and Plates
for Assay Development

Cytokine ELISA Kits and
Related Research Products

ELSIA Assay Formats - Direct, Indirect, Sandwich
Common ELISA formats. In the assay, the antigen of interested is be immobilized by direct adsorption to the assay plate or by first attaching a capture antibody to the plate surface. Detection of the antigen can then be performed using an enzyme-conjugated primary antibody (direct detection) or a matched set of unlabeled primary antibody and conjugated secondary antibodies (indirect detection).

Direct vs. Indirect Detection ELISA Formats

The direct detection method uses a labeled primary antibody that reacts directly with the antigen. Direct detection can be performed with antigen that is directly immobilized on the assay plate or with the capture assay format. Direct detection is not widely used in ELISA but is quite common for immunohistochemical staining of tissues and cells.

The indirect detection method uses a labeled secondary antibody for detection and is the most popular format for ELISA. The secondary antibody has specificity for and the primary antibody. In a sandwich ELISA, it is critical that the secondary antibody be specific for the detection primary antibody only (and not the capture antibody) or the assay will not be specific for the antigen. Generally, this is achieved by using capture and primary antibodies from different host species (e.g., mouse IgG and rabbit IgG, respectively). For sandwich assays, it is beneficial to use secondary antibodies that have been cross-adsorbed to remove any antibodies that have affinity for the capture antibody.

Learn more...
Overview of Detection Probes

Comparison of Direct and Indirect ELISA Detection Methods.
Direct Detection Advantages
  • Quick because only one antibody and fewer steps are used.
  • Cross-reactivity of secondary antibody is eliminated.
Disadvantages
  • Immunoreactivity of the primary antibody might be adversely affected by labeling with enzymes or tags.
  • Labeling primary antibodies for each specific ELISA system is time-consuming and expensive.
  • No flexibility in choice of primary antibody label from one experiment to another.
  • Minimal signal amplification.
Indirect Detection Advantages
  • A wide variety of labeled secondary antibodies are available commercially.
  • Versatile because many primary antibodies can be made in one species and the same labeled secondary antibody can be used for detection.
  • Maximum immunoreactivity of the primary antibody is retained because it is not labeled.
  • Sensitivity is increased because each primary antibody contains several epitopes that can be bound by the labeled secondary antibody, allowing for signal amplification.
  • Different visualization markers can be used with the same primary antibody.
Disadvantages
  • Cross-reactivity might occur with the secondary antibody, resulting in nonspecific signal.
  • An extra incubation step is required in the procedure.

Selecting and Coating ELISA Plates

When developing a new ELISA for a specific antigen, the first step is to optimize the plate-coating conditions for the antigen or capture antibody. Begin by choosing an assay microplate (not tissue culture treated plates) with a minimum protein-binding capacity of 400 ng/cm². It is also important that the CV value (coefficient of variation) of the protein binding be low (<5% is preferred) so that there is limited deviation in values that should be identical in the assay results between wells and plates. The choice of plate color depends upon the signal being detected. Clear polystyrene flat bottom plates are used for colorimetric signals while black or white opaque plates are used for fluorescent and chemiluminescent signals. Visually inspect plates before use as imperfections or scratches in the plastic will cause aberrations when acquiring data from the developed assay.

Plate coating is achieved through passive adsorption of the protein to the plastic of the assay microplate. This process occurs though hydrophobic interactions between the plastic and non-polar protein residues. Although individual proteins may require specific conditions or pretreatment for optimal binding, the most common method for coating plates involves adding a 2-10 μg/ml solution of protein dissolved in an alkaline buffer such as phosphate-buffered saline (pH 7.4) or carbonate-bicarbonate buffer (pH 9.4). The plate is left to incubate for several hours to overnight at 4-37°C. Typically, after removing the coating solution, blocking buffer is added to ensure that all remaining available binding surfaces of the plastic well are covered (see subsequent discussion). Coated plates can be used immediately or dried and stored at 4°C for later use, depending on the stability of the coated protein.

It is important to note that optimal coating conditions can vary with each protein. With the exception of competition ELISAs, the plates are coated with more capture protein than can actually be bound during the assay in order to facilitate the largest working range of detection possible. Some proteins, especially antibodies, are best coated on plates at a concentration lower than the maximum binding capacity in order to prevent nonspecific binding in later steps by a phenomenon called "hooking". Hooking results from proteins getting trapped between the coating proteins which prevents effective washing and removal of non bound proteins. When hooking nonspecifically traps detection primary and secondary antibodies, high background signal results lowering the signal to noise ratio and thus sensitivity of an assay.

View Products...
Pierce 96-Well Microplates
Pierce 8-Well Strip Microplates
Prepared Buffers
Reagent Reservoirs
Microplate Sealing Tape

Pre-coated ELISA Plates

For antibodies and proteins, coating plates by passive adsorption usually works well. However, problems can arise from passive adsorption, including improper orientation, denaturation, poor immobilization efficiency and binding of contaminants along with the target molecule. Antibodies can be attached to a microplate through the Fc region using Protein A, G, or A/G coated plates, which orients them properly and preserves their antigen binding capability. Fusion proteins can be attached to a microplate in the proper orientation using glutathione, metal-chelate, or capture-antibody coated plates. Peptides and other small molecules, which typically do not bind effectively by passive adsorption, can be biotinylated and attached with high efficiency to a streptavidin or NeutrAvidin Protein coated plate. Biotinylated antibodies also can be immobilized on plates precoated with biotin-binding proteins. Using pre-coated plates in this manner physically separates the antigen or capture antibody from the surface of the plate as protection from its denaturing effects.

View Products...
Protein A/G Coated Plates
Antibody Coated Plates
Streptavidin Coated Plates
NeutrAvidin Coated Plates

Browse all Coated Plates

Antibodies and Probes for ELISA

Either monoclonal or polyclonal antibodies can be used as the capture and detection antibodies in sandwich ELISA systems. Monoclonals have an inherent monospecificity toward a single epitope that allows fine detection and quantitation of small differences in antigen. A polyclonal is often used as the capture antibody to pull down as much of the antigen as possible. Then a monoclonal is used as the detecting antibody in the sandwich assay to provide improved specificity.

An important consideration in designing a sandwich ELISA is that the capture and detection antibodies must recognize two different non-overlapping epitopes. When the antigen binds to the capture antibody, the epitope recognized by the detection antibody must not be obscured or altered. Capture and detection antibodies that do not interfere with one another and can bind simultaneously are called "matched pairs" and are suitable for developing a sandwich ELISA. Many primary antibody suppliers provide information about epitopes and indicate pairs of antibodies that have been validated in ELISA as matched pairs.

Another design consideration in choosing antibodies is cost. A polyclonal antibody is generally less expensive (~5 fold) to produce than a monoclonal. The specificity gained by using monoclonals for both the capture and detecting antibody must be weighed against the cost and time required for producing two monoclonal antibodies. Preparing a “self-sandwich” ELISA assay, where the same antibody is used for the capture and detection, can limit the dynamic range and sensitivity of the final ELISA.

View Products...
Primary Antibodies
Secondary Antibodies
and Conjugates

Selection Guide...
Secondary Antibody
Selection Guide

Blocking Buffers and Wash Buffers

The binding capacity of microplate wells is typically higher than the amount of protein coated in each well. The remaining surface area must be blocked to prevent antibodies or other proteins from adsorbing to the plate during subsequent steps. A blocking buffer is a solution of irrelevant protein, mixture of proteins, or other compound that passively adsorbs to all remaining binding surfaces of the plate. The blocking buffer is effective if it improves the sensitivity of an assay by reducing background signal and improving the signal-to-noise ratio. The ideal blocking buffer will bind to all potential sites of nonspecific interaction, eliminating background altogether, without altering or obscuring the epitope for antibody binding.

When developing any new ELISA, it is important to test several different blockers for the highest signal:noise ratio in the assay. Many factors can influence nonspecific binding, including various protein:protein interactions unique to the samples and antibodies involved. The most important parameter when selecting a blocker is the signal:noise ratio, which is measured as the signal obtained with a sample containing the target analyte as compared to that obtained with a sample without the target analyte. Using inadequate amounts of blocker will result in excessive background and a reduced signal:noise ratio. Using excessive concentrations of blocker may mask antibody-antigen interactions or inhibit the enzyme, again causing a reduction of the signal:noise ratio. No single blocking agent is ideal for every occasion and empirical testing is essential for true optimization of the blocking step.

In addition to blocking, it is essential to perform thorough washes between each step of the ELISA. Washing steps are necessary to remove nonbound reagents and decrease background, thereby increasing the signal:noise ratio. Insufficient washing will allow high background, while excessive washing might result in decreased sensitivity caused by elution of the antibody and/or antigen from the well. Washing is performed in a physiologic buffer such as Tris-buffered saline (TBS) or phosphate-buffered saline (PBS) without any additives. Usually, a detergent such as 0.05% Tween-20 is added to the buffer to help remove nonspecifically bound material. Another common technique is to use a dilute solution of the blocking buffer along with some added detergent. Including the blocking agent and adding a detergent in wash buffers helps to minimize background in the assay. For best results, use high-purity detergents to prevent introduction of impurities that will interfere with the assay such enzyme inhibitors or peroxides.

Learn more...
Blocking Buffers


View Products...
Protein Blocking Buffers
   (BSA, Casein, Milk, etc.)
SuperBlock Blocking Buffers
StartingBlock Blocking Buffers
Protein-Free Blocking Buffers
Surfact-Amps Detergents

Detection Strategies for ELISA

The final stage in all ELISA systems is a detection step. Unless a radioactive or fluorescent tag was used, this involves the introduction of an enzyme substrate.The enzyme converts the substrate to a detectable product. If an ELISA has been constructed and developed properly, then the intensity of signal produced when the substrate is added will be directly proportional to the amount of antigen captured in the plate and bound by the detection reagents. Enzyme-conjugated antibodies (especially those involving horseradish peroxidase, HRP) offer the most flexibility in detection and documentation methods for ELISA because of the variety of substrates available for chromogenic, chemifluorescent and chemiluminescent imaging.

Though not as sensitive as fluorescent or chemiluminescent substrates, chromogenic ELISA substrates allow direct visualization and enable kinetic studies to be performed. Furthermore, chromogenic ELISA substrates are detected with standard absorbance plate readers common to many laboratories. Fluorescent ELISA substrates are not as common and require a fluorometer that produces the correct excitation beam to cause signal emission to be generated from the fluorescent tag. Though best used with a luminometer plate reader, chemiluminescent substrates can be detected by various means including digital camera systems. Once draw back of using chemiluminescent substrates for ELISA is the signal intensity can vary more with than other substrates. For assays requiring many plates to be read, this can present a problem if the signal begins to decay before plates are read. For this reason, it is important to make sure the assay has been optimized with the substrate in order to ovoid misinterpreting signal-fade in a sample as low antigen abundance.

View Products...
Selection Guide for
ELISA Substrates

ELISA Kits, ELISPOT and In-Cell ELISA

In addition to the individual components and general principles of ELISA discussed in this article, complete kits are available for detection of specific cytokines and other targets, such as interferon gamma (IFN gamma) and interleukin 6 (IL-6). ELISA development kits (Mini Kits and Screening Sets) for specific targets include only matched pairs of antibodies and a protocol for coating plates. The ELISA Mini Kits are an economical way to setup and perform large scale assays (up to forty 96-well microwell plates) while the ELISA Screening Sets allow rapid screening of up to five 96-well microplates.

ELISPOT kits (enzyme-linked immunospot assay) for measurement of cytokines in single cells are available for human IFN gamma, IL-2 and TNF alpha. An alternative ELISPOT for application to nearly any specific analyte for which antibodies exist is the In-Cell ELISA, developed for performing ELISA assays on plated cells. The Thermo Scientific In-Cell ELISA Kits are available for detection by colorimetric or fluorescent (Near-IR) instrumentation and include all reagents necessary except the primary antibody. The colorimetric version of the In-Cell ELISA is developed using a TMB substrate for HRP, while the Near-IR detection kit uses secondary detection reagents conjugated to DyLight Fluors. Both types of In-Cell ELISA Kits allow multiple target proteins to be compared to each other in the same assay either through normalization or multiplex analysis.

Cytokine ELISA...
ELISA Kits

ELISA Mini Kits
ELISA Screening Sets

Cytokine ELISPOT...
ELISPOT Kits

Specialized ELISA Kits...
In-Cell ELISA Kits

Browse all Thermo Scientific Pierce ELISA Reagents

 

Learn more about other Thermo Scientific Life Science Research Products
Biopolymers Cell Culture High Content Screening  
Nucleic Acid Technologies PCR Reagents & Plastics RNAi Technologies  European Sales

 © 2010 Thermo Fisher Scientific Inc.

PO Box 117, Rockford, IL 61105 USA
1-800-874-3723  or  815-968-0747

Trademarks Privacy Statement