Thermo Scientific - Pierce Protein Research Products



Advanced Search 
Part of Thermo Fisher Scientific  

Document Center

  Certificate of Analysis
  Product Instructions
  MSDS
  Print This Page
  Request A Catalog

User Profile

Email Address:
Password:
 
  I Forgot My Password
  Register
  Why Register?

Shopping Cart

  Ordering Information
Shipping Info
Credit Info
Returns Info
  Current Order
Currently Empty
Order Form


Subscribe to our RSS feed! RSS

 


YOU ARE HERE:  Browse Product Catalog > Western Blotting, ELISA and Cell Imaging > Western Blotting Substrates and Reagents > Restore Western Blot Stripping Buffer  


Restore Western Blot Stripping Buffer 

Strip time off your research safely and effectively.

Restore Western Blot Stripping Buffer available in 5 liter size.Tired of re-running electrophoresis gels and waiting to see your results? Although optimizing assay conditions is the best way to achieve optimum results, re-performing the gel electrophoresis process to test each new primary antibody or antibody concentration is time-consuming and expensive. You can forget about starting over when you use Thermo Scientific Restore Western Blot Stripping Buffer!

Highlights of Restore Western Blot Stripping Buffer:

  • Saves time – no need to re-run gels
  • Saves precious sample – re-probe the membrane using the same target sample
  • Provides efficient removal – proprietary formulation works better than "homemade" buffers
  • Gentle formulation – does not damage target protein after stripping and re-probing
  • Odor-free – no mercatans means no acrid odors
  • Economical – less expensive than other competing stripping buffers

Applications for Restore Western Blot Stripping Buffer

  • Test different primary antibodies – There’s no need to waste precious sample and re-run a gel to test different primary antibodies. Simply strip the membrane with Restore Stripping Buffer to remove the first primary antibody and set of reagents. It takes only 5-15 minutes, depending on the affinity of the primary antibody. After stripping, re-probe with a new primary antibody (see figure).
  • Optimize assay conditions – Using Thermo Scientific SuperSignal West Substrates, secondary antibody concentrations can be optimized after a single stripping and re-probing cycle (see figure). A chemiluminescent detection system is the most sensitive method to detect any reagent still bound after the stripping procedure.

Restore PLUS Western Blot Stripping Protocol:

  • Wash blot to remove chemiluminescent substrate
  • Incubate in Restore Western Blot Stripping Buffer for 5-15 minutes at room temperature
  • Remove blot and wash in Wash Buffer
  • Block membrane
  • Test for sufficient removal of antibodies
  • Perform next immunoprobing experiment
 panel blots showing stripping and reprobing for JAK-1 and Bak protein with Restore Western Blot Stripping Buffer.
Re-probing with different antibodies. Western blots of HeLa cell lysate protein (diluted from 750 ng to 83.3 ng) were detected with SuperSignal West Dura Chemiluminescent Substrate. The first blot used polyclonal rabbit anti-JAK-1 primary antibody at 1:2,000 dilution with an HRP-secondary conjugate diluted at 1:350,000. The same blot was stripped for 5 minutes at room temperature in Restore Western Blot Stripping Buffer and then re-probed with purified mouse anti-human Bak monoclonal primary antibody at 1:1,000 with the HRP-secondary conjugate at 1:100,000. Five-percent nonfat milk with 0.05% Tween*-20 was used for blocking.

 

3 Panel image showing two antibody concentrations used to optimize probing for IL-2 on a Western Blot using Restore Western Blot Stripping Buffer.
Reprobing with different antibodies.Antibody optimization study. Western blots of Interleukin-2 (diluted 20-0.156 ng) were detected using SuperSignal West Pico Chemiluminescent Substrate. The first blot (A) used the primary antibody diluted to 1/1,000 (0.5 µg/ml) of rat anti-mouse IL-2 and the horseradish peroxidase (HRP)-labeled goat anti-rat secondary antibody (Product # 31470) diluted 1/5,000. The same blot was stripped with Restore Western Blot Stripping Buffer (B) for 5 minutes at room temperature and re-probed (C) with the primary antibody at 1/5,000 and the HRP-secondary conjugate at 1:20,000. Thermo Scientific SuperBlock Blocking Buffer was used for blocking.

 

References:

  1. Kaufmann, S.H., et al. (1987). Anal. Biochem. 161: 89-95.
  2. Kaufmann, S.H. and Kellner, U. (1998). Erasure of Western blots after autoradiographic or chemiluminescent detection. In Immunochemical Protocols. Ed. Pound, J.D. Humana Press, Totowa, NJ, 223-235.
  3. Schrager, J.A., et al. (2002). J. Biol. Chem. 277: 6137-6142.
  4. Sorci, G., et al. (20036). Mol. Cell. Biol. 23: 4870-4881.

Related Products and Links:
Restore PLUS Western Blot Stripping Buffer – stronger formulation for tenacious antibodies
Restore Fluorescent Western Blot Stripping Buffer – formulated for fluorescent blotting on PVDF
Blocking Buffers – choose from protein-based and protein-free blocking buffers
Chemiluminescent Substrates – compare substrates to the choose the best for your application
CL-XPosure Film – X-ray film for chemiluminescent detection
Background Eliminator for Film – remove excess signal from film to make data clearer


Ordering Information
Certificate of AnalysisCertificate of Analysis   Product InstructionsProduct Instructions   MSDSMSDS
Buy Product # Description Pkg. Size Files Price
Add 21062 Restore Western Blot Stripping Buffer, Trial Size 30ml Product Instructions MSDS $32.00
Add 21059 Restore Western Blot Stripping Buffer
Sufficient for stripping 25 (8cm x 10cm) blots.
500ml Product Instructions MSDS $110.00
Add 21063 Restore Western Blot Stripping Buffer
Sufficient for stripping 250 (8cm x 10cm) blots.
5L Product Instructions MSDS $450.00

Learn more about other Thermo Scientific Life Science Research Products
Biopolymers Cell Culture High Content Screening  
Nucleic Acid Technologies PCR Reagents & Plastics RNAi Technologies  European Sales

 © 2009 Thermo Fisher Scientific Inc.

PO Box 117, Rockford, IL 61105 USA
1-800-874-3723  or  815-968-0747

Trademarks Privacy Statement